The
SV SERIES of SCANNER/VERIFIERS are ON-LINE VERIFIERS
The
SV Series analyzes and reports virtually every verification
parameter known. ANSI and Traditional print quality parameters
are transmitted along with decoded data. The reported symbol
quality parameters ensure the print method or complete bar code
process is optimized. This is important for ISO corrective
action procedures, label manufacturing and printing, tracking
systems, ink jet applications and more.
The
SV SERIES of SCANNER/VERIFIERS are FIXED POSITION SCANNERS
The
SV Series can operate as a fixed position scanner. But, since it
also provides diagnostic bar code quality information, it can reduce
system downtime and save material costs. It does this by
isolating the source of the problem. Once the source of the
problem is found, it can be corrected before non-readable bar codes
are printed and material is wasted.
The
diagnostic capability is also useful when installing the scanner or
after a conveyor or printer maintenance cycle. The available
print quality information gives an indication of first time read
rates, optimal scanner alignment, optimal conveyor speed and optimal
printer settings and adjustments. In short, everything that is
needed to ensure proper set-up of a system.
|
| |
|
| |
|
EASY
SETUP / FLEXIBLE INTERFACE
|
The
SV Series uses a serial port to interface with RJS
ScanVision, a PC based software package used for
set-up and monitoring. Use ScanVision for SV
setup while the scanner/verifier is off line and/or
use it for real-time bar code quality analysis while
the scanner/verifier is operating. The unit also
incorporates Model SV download language for setup
without RJS ScanVision.
Five
hardware outputs are available via an I/O-Power port
for logic operation such as No Read, Poor Quality,
Good Quality or Good Read status. Two synchronization
inputs are also available for robust No Read
evaluations. Two LED’s are available for status
indications.
The
serial port can also be used without ScanVision to
provide decoded data and/or bar code analysis
information to a host system.
|
|

|
|
| |
RJS
MODEL SV SERIES SYSTEM DESCRIPTION and TECHNICAL DATA
SV
Series Model Specifications*
|
|
SV100
|
SV100HD
|
SV100C
|
SV200-1
|
SV200-2
|
|
Analyses/sec
|
100
|
100
|
100
|
200
|
200
|
|
Beam
Width
|
6"
(152mm)
|
4.5"
(114mm)
|
10.5"
(267mm)
|
2.5"
(63.5mm)
|
1.75"
(44mm)
|
|
Focus
Distance
|
8"
(203 mm)
|
6"
(152mm)
|
15"
(381mm)
|
8"
(203mm)
|
6"
(152mm)
|
|
X
dim (min)
|
.0067"
(.17mm)
|
.005"
(.127mm)
|
.013"
(.33mm)
|
.0067"
(.17mm)
|
.005"
(.127mm)
|
*
Contact RJS Technical Support for information on custom and other
models
Accessories
and Options
Universal
Power Supply Unit, RJS ScanVision Software, Female DB-9 to Female
DB-9 Communication Cable (6 ft. (1.8 M) length), Calibration Symbol,
Mounting Stand, Rastering Scan Line, Interface Kits for Zebra and
Sato Printers (contact RJS for additional printer types), Power
Supply/Sensor/Output Cable.
Data
and Quality Parameters Available**
Decoded
Data, All Symbol Characters, Modulo Check Digit Analysis, Symbology
Type, ANSI Method Overall Symbol Grade, ANSI Method Parameter
Grades, (Reference Decode, Decodability, Modulation, Symbol
Contrast, Rmin/Rmax, Defects, Min. Edge Contrast and Global
Threshold), Average Bar Deviation, Ratio (if applicable), PCS,
Element Reflectance (min. and max.), Quiet Zone Analysis, X
Dimension, Inter-Character Gap (if applicable), No Read Flag, %
decode, Partial Read Analysis, Pass/Fail Flag, Data Match (up to ten
(10) fields), Increment/Decrement (base 10 and base 36).
**
Note:
1. All reflectance parameters require calibration, fixed scanning
distance and fixed angle of scan
2. X dimension requires fixed scanning distance
Symbologies
USS
Code 39, USS Code 128, USS Code 93, USS Codabar, USS Interleaved 2
of 5, UPC / EAN including 2 and 5 digit supplemental codes
(Contact RJS for special symbology applications.)
Scanning
Performance
Depth
of Field – Mount at specified focus distance for most accurate
verification operation.
Ladder or Picket Fence Bar Codes
Up to four (4) bar codes across
Operation
Modes
Sync
(edge and envelope), Freescan and ScanVision off line modes can be
enabled
Physical
Package:
4.4" (112 mm) x 2.4" (61 mm) x 5.2" (132 mm)
Indications: Five (5) LED’s – Power/Sync, Calibration, Read,
two (2) programmable LED’s
Comm Port: DB-9 male, RS 232C, programmable baud rate up to 115200
baud
I/O-Power: DB-15 male, five (5) programmable outputs, two (2) sync
inputs
+5VDC @ 1 amp required
Mounting: Two (2) sets of mounting holes on two (2) different
surfaces or a clamp for tightening to a 3/8" (9.5 mm) rod.
RJS
SV Series Scanner/Verifier
Statement of Compliance
The
RJS Series of Scanner/Verifiers gathers data per the ANSI/ISO
method of verification to perform practically all the industry
standard bar code quality parameter calculations. These include
all ANSI/ISO method parameters, PCS, ratio, X dimension
calculation, modulo check digit calculations, average bar
deviation, etc.
Reflectance
Compliance – 660 nm wavelength (red) light
The reflectance values embedded in
the calibration symbol supplied with each SV unit are traceable to
Applied Image Primary Verification Calibrated Standard per ANSI
X3.182 Step Reflectance Chart (see note 2.) Applied Image
certified Calibration Standards are manufactured to Applied Image,
Inc. and Uniform Code Council, Inc. specifications, using ANSI
X3.182-1990 methodology, and are calibrated using standards
traceable to the National Institute of Standards and Technology
(N.I.S.T.)
ANSI/ISO
Method Compliance
The RJS SV Series gathers data and
performs all ANSI/ISO method parameter calculations per the
ISO/IEC 15416 and ANSI X3.182-1990 methodologies with a few
exceptions. The exceptions are related to the instrument’s
design and mission. The design incorporates a proprietary analog
laser scanner that can be assembled with various focus lengths to
produce different beam sizes. The mission is to not only analyze
bar code quality, but also to detect any printer failures, process
failures or media problems. For maximum performance, a fixed
mounting distance and angle are required. A beam spot size able to
detect errors of the particular print method is highly
recommended. This beam spot size may or may not correspond
to the recommendations in various specifications that it be
related to the X dimension of a particular symbol, but instead
correspond to the printer’s resolution or some other
parameter(s) critical in the application. A major philosophy of an
on-line verification system is; if the printer and/or process is
operating correctly and the media has proper reflectance
properties, the best print quality for that particular print
method and material is achieved by definition.
Notes
1.
The SV Series can be calibrated to practically any
reflectance standard. Internal high and low calibration
reflectance normalization settings are user programmable via
commands.
2.
Final system tests are performed at the proper focus
distance and at an angle of 22 degrees. Units with common focus
distances are checked to yield analysis results within +/- 4 % of
all target values.
3.
SV models with an 8 inch focus distance have a spot size
that gathers light very similar to a 6 mil round aperture. For
these models, final test includes analyzing UPC symbols on the
Calibrated Conformance Standard Test Card for EAN/UPC Symbol
Verifiers. Results are checked to be within +/- 4% of the marked
values on the test card. SV100 and SV200-1 are examples of models
with a focus distance of 8 inches.
Exceptions
to the ANSI/ISO method
1.
The Defects calculation does not include the quiet zone
area. A separate quiet zone check is implemented to easier isolate
print problems vs. setup problems in an on-line environment.
2.
A laser spot is used instead of a round aperture. The spot
size is dependent on the focus distance of the unit’s optical
system.
|
| |
|
| |
RJS PRODUCT LIST
| Product |
Part
Number |
|
SV SERIES
VERIFICATION PRODUCTS
|
| SV100
SCANNER/VERIFIER (medium density codes (6.6 – 40 mil X) |
002-7973 |
| SV100HD
SCANNER/VERIFIER (for high density symbols (5 - 20 mil X) |
002-8099 |
| SV100C
SCANNER/VERIFIER (low density codes, corrugated
applications) |
002-8102 |
| SV200-1 SCANNER
/VERIFIER (higher speed, medium density applications) |
002-8119 |
| SV200-2
SCANNER/VERIFIER (higher speed, high density applications) |
002-8254 |
| |
|
SV SERIES
ACCESSORIES
|
| SATO2
8400/8450/CL608/CL408 INTERFACE CABLE (incl. universal
PSU) |
002-8106 |
NOTE:
If used w/re-winder, Sato Power Supply part # 11S000120
required Power Supply must be purchased through Sato
Distribution
|
| ZEBRA2
105S/105SE/160S INTERFACE CABLE (incl. universal PSU) |
002-8105 |
| ZEBRA2
Z105SL INTERFACE CABLE (incl. universal PSU)4 |
176240-001 |
| ZEBRA2
Z4M/Z6M INTERFACE CABLE (incl. universal PSU)4 |
176239-001 |
| ZEBRA2
XiII/XiIII/III PLUS INTERFACE KIT 4 |
002-8098 |
|
Includes: Interface PCB, universal PSU, verifier cable |
| ALTERNATE
ZEBRA2
XiII INTERFACE KIT 4 |
002-8248 |
|
Includes: Interface PCB, universal PSU, printer EPROMs,
verifier cable |
ALTERNATE
ZEBRA2
XiIII/III PLUS INTERFACE KIT4
Includes: Interface PCB, universal PSU, verifier cable
(special printer firmware required) |
176088-100 |
| ALTERNATE
ZEBRA2
XiII/III/III PLUS INTERFACE CABLE (incl. universal PSU) |
002-8153 |
| ZEBRA2
Xi INTERFACE CABLE (incl. universal PSU) 4 |
002-8104 |
| DATAMAX
I/W CLASS INTERFACE CABLE (SV SERIES & OLI5000) 5 |
173875-001 |
| INSTALLATION KIT
(ScanVision, universal PSU, power and comm cables) |
002-8107 |
| POWER
SUPPLY (universal PSU and cable) |
002-7766 |
| COMMUNICATION
CABLE (null modem) |
002-7639 |
| POWER
SUPPLY/SENSOR/OUTPUT CABLE (incl. universal PSU ) 3 |
002-8344 |
| STANDARD
MOUNTING STAND ASSEMBLY |
002-4608 |
| “SKY
HOOK” MOUNTING STAND ASSEMBLY |
002-7972 |
| ADDITIONAL SV
MANUAL (manuals are included with SV units) |
002-7942 |
| ScanVision
(PC software for setup and monitoring) |
002-7974 |
| ScanVision
MANUAL (manuals are included with ScanVision) |
002-8151 |
| |
|
1
Requires Zebra applicator board and specific printer
EPROMs (contact RJS for info)
2 Zebra is a registered trademark of Zebra Technologies
Corp.
Sato is a registered
trademark of Sato Corp.
3 Designed to interface with a Banner Mini-Beam sensor
(sensor not included with cable)
Mini-Beam is a trademark of
Banner Engineering Corporation
4 Contact RJS Technical Support for Application Details
and System Limits
5 Requires GPIO port installed in printer |
|
|